{"id":735,"date":"2026-11-20T04:23:00","date_gmt":"2026-11-20T03:23:00","guid":{"rendered":"https:\/\/blumhost.net\/blog\/?p=735"},"modified":"2026-11-05T20:26:15","modified_gmt":"2026-11-05T19:26:15","slug":"pue-datacenter-que-es","status":"publish","type":"post","link":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/","title":{"rendered":"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia energ\u00e9tica de un CPD"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">El <strong>PUE (Power Usage Effectiveness)<\/strong> indica cu\u00e1nta energ\u00eda consume un datacenter en total por cada vatio que llega a los servidores. Un PUE de 1,5 significa que, por cada 1 kW de IT, el edificio gasta 0,5 kW adicionales en refrigeraci\u00f3n, p\u00e9rdidas el\u00e9ctricas e iluminaci\u00f3n. <strong>Cuanto m\u00e1s cerca de 1, m\u00e1s eficiente<\/strong>.<\/p>\n\n\n\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_74 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Tabla de Contenidos<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Alternar tabla de contenidos\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Como_se_calcula_el_PUE\" >C\u00f3mo se calcula el PUE<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Que_consume_energia_ademas_de_los_servidores\" >Qu\u00e9 consume energ\u00eda adem\u00e1s de los servidores<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Que_valores_de_PUE_son_buenos\" >Qu\u00e9 valores de PUE son buenos<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Como_mejora_un_datacenter_su_PUE\" >C\u00f3mo mejora un datacenter su PUE<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Las_limitaciones_del_PUE\" >Las limitaciones del PUE<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Por_que_importa_el_PUE_al_contratar_housing\" >Por qu\u00e9 importa el PUE al contratar housing<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Coste\" >Coste<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Sostenibilidad_e_informes_ESG\" >Sostenibilidad e informes ESG<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Comparativa_con_tu_CPD_propio\" >Comparativa con tu CPD propio<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Que_preguntar_a_tu_proveedor\" >Qu\u00e9 preguntar a tu proveedor<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Preguntas_frecuentes\" >Preguntas frecuentes<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#Housing_en_un_datacenter_moderno\" >Housing en un datacenter moderno<\/a><\/li><\/ul><\/nav><\/div>\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Como_se_calcula_el_PUE\"><\/span>C\u00f3mo se calcula el PUE<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<pre class=\"wp-block-code\"><code>\\text{PUE} = \\frac{\\text{Energ\u00eda total del datacenter}}{\\text{Energ\u00eda de los equipos IT}}<\/code><\/pre>\n\n\n\n<p class=\"wp-block-paragraph\">Ejemplo: un datacenter consume 1.500 MWh al a\u00f1o y sus servidores, switches y almacenamiento consumen 1.000 MWh. Su PUE es 1.500 \/ 1.000 = <strong>1,5<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">La m\u00e9trica la cre\u00f3 The Green Grid y est\u00e1 normalizada en la ISO\/IEC 30134-2. Su inversa se llama <strong>DCiE<\/strong>: un PUE de 1,5 equivale a un DCiE del 67 %.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Que_consume_energia_ademas_de_los_servidores\"><\/span>Qu\u00e9 consume energ\u00eda adem\u00e1s de los servidores<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Refrigeraci\u00f3n<\/strong>: enfriadoras, unidades CRAC\/CRAH, ventiladores, bombas. Es la partida m\u00e1s grande.<\/li>\n\n\n\n<li><strong>P\u00e9rdidas el\u00e9ctricas<\/strong>: transformadores, UPS y distribuci\u00f3n.<\/li>\n\n\n\n<li><strong>Iluminaci\u00f3n, seguridad y oficinas<\/strong> del propio edificio.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Que_valores_de_PUE_son_buenos\"><\/span>Qu\u00e9 valores de PUE son buenos<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>PUE<\/th><th>Valoraci\u00f3n<\/th><th>Energ\u00eda extra por cada kW de IT<\/th><\/tr><tr><td>2,0 o m\u00e1s<\/td><td>Ineficiente (salas antiguas, CPD de oficina)<\/td><td>1 kW o m\u00e1s<\/td><\/tr><tr><td>1,5-1,8<\/td><td>En la media del sector<\/td><td>0,5-0,8 kW<\/td><\/tr><tr><td>1,2-1,4<\/td><td>Eficiente<\/td><td>0,2-0,4 kW<\/td><\/tr><tr><td>&lt; 1,2<\/td><td>Excelente (hiperescala, clima fr\u00edo)<\/td><td>&lt; 0,2 kW<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Las encuestas anuales de Uptime Institute sit\u00faan la media mundial en torno a 1,5-1,6 en los \u00faltimos a\u00f1os. Un cuarto de servidores en una oficina suele estar muy por encima de 2.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Como_mejora_un_datacenter_su_PUE\"><\/span>C\u00f3mo mejora un datacenter su PUE<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Confinamiento de pasillos<\/strong> fr\u00edos y calientes: evita que el aire se mezcle.<\/li>\n\n\n\n<li><strong>Free cooling<\/strong>: aprovechar el aire exterior cuando la temperatura lo permite.<\/li>\n\n\n\n<li><strong>Temperaturas de consigna m\u00e1s altas<\/strong>, dentro de los rangos que admiten los equipos.<\/li>\n\n\n\n<li><strong>UPS de alta eficiencia<\/strong> y distribuci\u00f3n en media tensi\u00f3n.<\/li>\n\n\n\n<li><strong>Paneles ciegos<\/strong> en los racks y cableado ordenado.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Las_limitaciones_del_PUE\"><\/span>Las limitaciones del PUE<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>No mide el consumo de los servidores<\/strong>: un datacenter lleno de equipos ineficientes puede tener buen PUE.<\/li>\n\n\n\n<li><strong>Depende del clima y la estaci\u00f3n<\/strong>: compara siempre PUE anuales.<\/li>\n\n\n\n<li><strong>Mejora con la ocupaci\u00f3n<\/strong>: un datacenter casi vac\u00edo suele tener peor PUE.<\/li>\n\n\n\n<li><strong>No mide agua ni carbono<\/strong>: para eso existen WUE (uso de agua) y CUE (emisiones de carbono).<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Por_que_importa_el_PUE_al_contratar_housing\"><\/span>Por qu\u00e9 importa el PUE al contratar housing<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Coste\"><\/span>Coste<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">El precio de la potencia que pagas incluye la energ\u00eda de refrigeraci\u00f3n y p\u00e9rdidas. Un datacenter eficiente tiene menos costes que trasladar.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Sostenibilidad_e_informes_ESG\"><\/span>Sostenibilidad e informes ESG<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Si tu empresa reporta su huella de carbono, la energ\u00eda de tus servidores en housing forma parte de ella. Con la Directiva europea de eficiencia energ\u00e9tica, los datacenters de cierto tama\u00f1o deben informar de sus indicadores energ\u00e9ticos, PUE incluido.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Comparativa_con_tu_CPD_propio\"><\/span>Comparativa con tu CPD propio<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Sacar los servidores de una sala de oficina con PUE de 2 o m\u00e1s a un datacenter profesional reduce la energ\u00eda total consumida por tu infraestructura, aunque los servidores consuman lo mismo.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Que_preguntar_a_tu_proveedor\"><\/span>Qu\u00e9 preguntar a tu proveedor<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u00bfCu\u00e1l es el PUE anual medio del datacenter?<\/li>\n\n\n\n<li>\u00bfQu\u00e9 sistemas de refrigeraci\u00f3n usa y si tiene free cooling?<\/li>\n\n\n\n<li>\u00bfQu\u00e9 parte de su energ\u00eda es renovable o con garant\u00eda de origen?<\/li>\n\n\n\n<li>\u00bfPublica WUE o CUE?<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Preguntas_frecuentes\"><\/span>Preguntas frecuentes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfQu\u00e9 significa PUE 1,0?<\/strong> Que toda la energ\u00eda va a los equipos IT. Es el ideal te\u00f3rico, inalcanzable en la pr\u00e1ctica.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfUn PUE bajo significa energ\u00eda verde?<\/strong> No. Mide eficiencia, no origen de la energ\u00eda.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u00bfC\u00f3mo afecta el PUE a mi factura de housing?<\/strong> Indirectamente: el precio por vatio incluye la refrigeraci\u00f3n y las p\u00e9rdidas de la instalaci\u00f3n.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Housing_en_un_datacenter_moderno\"><\/span>Housing en un datacenter moderno<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">El <a target=\"_blank\" rel=\"noopener\" href=\"https:\/\/blumhost.net\/housing\">housing de BlumHost<\/a> est\u00e1 en IaaS Datacenter Madrid, una instalaci\u00f3n de nueva construcci\u00f3n con climatizaci\u00f3n de precisi\u00f3n y monitorizaci\u00f3n 24\/7. Preg\u00fantanos por los datos de eficiencia de la instalaci\u00f3n al pedir tu presupuesto.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>El PUE (Power Usage Effectiveness) indica cu\u00e1nta energ\u00eda consume un datacenter en total por cada vatio que llega a los servidores. Un PUE de 1,5 significa que, por cada 1 kW de IT, el edificio gasta 0,5 kW adicionales en&hellip;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[77],"tags":[],"class_list":["post-735","post","type-post","status-publish","format-standard","hentry","category-guias-para-principiantes"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia - Blog de BlumHost<\/title>\n<meta name=\"description\" content=\"Qu\u00e9 es el PUE (Power Usage Effectiveness), c\u00f3mo se calcula, qu\u00e9 valores son buenos, sus limitaciones y por qu\u00e9 importa al elegir un proveedor de housing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia - Blog de BlumHost\" \/>\n<meta property=\"og:description\" content=\"Qu\u00e9 es el PUE (Power Usage Effectiveness), c\u00f3mo se calcula, qu\u00e9 valores son buenos, sus limitaciones y por qu\u00e9 importa al elegir un proveedor de housing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog de BlumHost\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/BlumHost\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-20T03:23:00+00:00\" \/>\n<meta name=\"author\" content=\"Miguel Taboada\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Miguel Taboada\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/\"},\"author\":{\"name\":\"Miguel Taboada\",\"@id\":\"https:\/\/blumhost.net\/blog\/#\/schema\/person\/33aa890af362ded38723fc4c1ef65ee7\"},\"headline\":\"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia energ\u00e9tica de un CPD\",\"datePublished\":\"2026-11-20T03:23:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/\"},\"wordCount\":651,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/blumhost.net\/blog\/#organization\"},\"articleSection\":[\"Gu\u00edas para principiantes\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/\",\"url\":\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/\",\"name\":\"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia - Blog de BlumHost\",\"isPartOf\":{\"@id\":\"https:\/\/blumhost.net\/blog\/#website\"},\"datePublished\":\"2026-11-20T03:23:00+00:00\",\"description\":\"Qu\u00e9 es el PUE (Power Usage Effectiveness), c\u00f3mo se calcula, qu\u00e9 valores son buenos, sus limitaciones y por qu\u00e9 importa al elegir un proveedor de housing.\",\"breadcrumb\":{\"@id\":\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Portada\",\"item\":\"https:\/\/blumhost.net\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia energ\u00e9tica de un CPD\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/blumhost.net\/blog\/#website\",\"url\":\"https:\/\/blumhost.net\/blog\/\",\"name\":\"Blog de BlumHost\",\"description\":\"Gu\u00eda completa con consejos pr\u00e1cticos, precios y ventajas reales para tu proyecto.\",\"publisher\":{\"@id\":\"https:\/\/blumhost.net\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/blumhost.net\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/blumhost.net\/blog\/#organization\",\"name\":\"Blog de BlumHost\",\"url\":\"https:\/\/blumhost.net\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/blumhost.net\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/blumhost.net\/blog\/wp-content\/uploads\/2025\/05\/cropped-blumhost.webp\",\"contentUrl\":\"https:\/\/blumhost.net\/blog\/wp-content\/uploads\/2025\/05\/cropped-blumhost.webp\",\"width\":240,\"height\":67,\"caption\":\"Blog de BlumHost\"},\"image\":{\"@id\":\"https:\/\/blumhost.net\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/BlumHost\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/blumhost.net\/blog\/#\/schema\/person\/33aa890af362ded38723fc4c1ef65ee7\",\"name\":\"Miguel Taboada\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/blumhost.net\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/bf9731b74ae636e457ef0ddcebbeb20f37a75f89668501ce0a80767a29e02722?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/bf9731b74ae636e457ef0ddcebbeb20f37a75f89668501ce0a80767a29e02722?s=96&d=mm&r=g\",\"caption\":\"Miguel Taboada\"},\"description\":\"Ingeniero en Telecomunicaciones e Inform\u00e1tica. Cre\u00e9 BlumHost para ofrecer un hosting distinto a los dem\u00e1s, que ofrezca la mejor atenci\u00f3n al cliente, al menor precio y con la mejor calidad.\",\"sameAs\":[\"https:\/\/blumhost.net\/\",\"https:\/\/es.linkedin.com\/in\/miguel-taboada-iglesias\"],\"url\":\"https:\/\/blumhost.net\/blog\/author\/miguel\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia - Blog de BlumHost","description":"Qu\u00e9 es el PUE (Power Usage Effectiveness), c\u00f3mo se calcula, qu\u00e9 valores son buenos, sus limitaciones y por qu\u00e9 importa al elegir un proveedor de housing.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/","og_locale":"es_ES","og_type":"article","og_title":"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia - Blog de BlumHost","og_description":"Qu\u00e9 es el PUE (Power Usage Effectiveness), c\u00f3mo se calcula, qu\u00e9 valores son buenos, sus limitaciones y por qu\u00e9 importa al elegir un proveedor de housing.","og_url":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/","og_site_name":"Blog de BlumHost","article_publisher":"https:\/\/www.facebook.com\/BlumHost","article_published_time":"2026-11-20T03:23:00+00:00","author":"Miguel Taboada","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Miguel Taboada","Tiempo de lectura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#article","isPartOf":{"@id":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/"},"author":{"name":"Miguel Taboada","@id":"https:\/\/blumhost.net\/blog\/#\/schema\/person\/33aa890af362ded38723fc4c1ef65ee7"},"headline":"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia energ\u00e9tica de un CPD","datePublished":"2026-11-20T03:23:00+00:00","mainEntityOfPage":{"@id":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/"},"wordCount":651,"commentCount":0,"publisher":{"@id":"https:\/\/blumhost.net\/blog\/#organization"},"articleSection":["Gu\u00edas para principiantes"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/","url":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/","name":"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia - Blog de BlumHost","isPartOf":{"@id":"https:\/\/blumhost.net\/blog\/#website"},"datePublished":"2026-11-20T03:23:00+00:00","description":"Qu\u00e9 es el PUE (Power Usage Effectiveness), c\u00f3mo se calcula, qu\u00e9 valores son buenos, sus limitaciones y por qu\u00e9 importa al elegir un proveedor de housing.","breadcrumb":{"@id":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/blumhost.net\/blog\/pue-datacenter-que-es\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Portada","item":"https:\/\/blumhost.net\/blog\/"},{"@type":"ListItem","position":2,"name":"PUE en datacenters: qu\u00e9 es y c\u00f3mo mide la eficiencia energ\u00e9tica de un CPD"}]},{"@type":"WebSite","@id":"https:\/\/blumhost.net\/blog\/#website","url":"https:\/\/blumhost.net\/blog\/","name":"Blog de BlumHost","description":"Gu\u00eda completa con consejos pr\u00e1cticos, precios y ventajas reales para tu proyecto.","publisher":{"@id":"https:\/\/blumhost.net\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blumhost.net\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/blumhost.net\/blog\/#organization","name":"Blog de BlumHost","url":"https:\/\/blumhost.net\/blog\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/blumhost.net\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/blumhost.net\/blog\/wp-content\/uploads\/2025\/05\/cropped-blumhost.webp","contentUrl":"https:\/\/blumhost.net\/blog\/wp-content\/uploads\/2025\/05\/cropped-blumhost.webp","width":240,"height":67,"caption":"Blog de BlumHost"},"image":{"@id":"https:\/\/blumhost.net\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/BlumHost"]},{"@type":"Person","@id":"https:\/\/blumhost.net\/blog\/#\/schema\/person\/33aa890af362ded38723fc4c1ef65ee7","name":"Miguel Taboada","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/blumhost.net\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/bf9731b74ae636e457ef0ddcebbeb20f37a75f89668501ce0a80767a29e02722?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bf9731b74ae636e457ef0ddcebbeb20f37a75f89668501ce0a80767a29e02722?s=96&d=mm&r=g","caption":"Miguel Taboada"},"description":"Ingeniero en Telecomunicaciones e Inform\u00e1tica. Cre\u00e9 BlumHost para ofrecer un hosting distinto a los dem\u00e1s, que ofrezca la mejor atenci\u00f3n al cliente, al menor precio y con la mejor calidad.","sameAs":["https:\/\/blumhost.net\/","https:\/\/es.linkedin.com\/in\/miguel-taboada-iglesias"],"url":"https:\/\/blumhost.net\/blog\/author\/miguel\/"}]}},"_links":{"self":[{"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/posts\/735","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/comments?post=735"}],"version-history":[{"count":1,"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/posts\/735\/revisions"}],"predecessor-version":[{"id":736,"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/posts\/735\/revisions\/736"}],"wp:attachment":[{"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/media?parent=735"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/categories?post=735"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blumhost.net\/blog\/wp-json\/wp\/v2\/tags?post=735"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}